TCX® (C) 331 150/250 (300) V
TCX® ( C ) 331 150/250V 1P0.75
Nexans ref. 10171239
- Packaging: Cut to length (m)
- Number of pairs: 1
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 7.4 mm
- Maximum outer diameter: 9.2 mm
- Approximate weight: 86 kg/km
TCX® ( C ) 331 150/250V 2P0.75
Nexans ref. 10171240
- Packaging: Cut to length (m)
- Number of pairs: 2
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 8.4 mm
- Maximum outer diameter: 10.5 mm
- Approximate weight: 139 kg/km
TCX® ( C ) 331 150/250V 4P0.75
Nexans ref. 10171242
- Packaging: Cut to length (m)
- Number of pairs: 4
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 12.0 mm
- Maximum outer diameter: 15.0 mm
- Approximate weight: 216 kg/km
TCX® ( C ) 331 150/250V 7P0.75
Nexans ref. 25405253
- Packaging: Cut to length (m)
- Number of pairs: 7
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 15.0 mm
- Maximum outer diameter: 18.5 mm
- Approximate weight: 346 kg/km
TCX® ( C ) 331 150/250V 10P0.75
Nexans ref. 10281588
- Packaging: Cut to length (m)
- Number of pairs: 10
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 21.0 mm
- Maximum outer diameter: 23.5 mm
- Approximate weight: 504 kg/km
TCX® ( C ) 331 150/250V 14P0.75
Nexans ref. 10186011
- Packaging: Cut to length (m)
- Number of pairs: 14
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 22.5 mm
- Maximum outer diameter: 25.0 mm
- Approximate weight: 628 kg/km
TCX® ( C ) 331 150/250V 19P0.75
Nexans ref. 10280537
- Packaging: Cut to length (m)
- Number of pairs: 19
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 25.5 mm
- Maximum outer diameter: 28.5 mm
- Approximate weight: 783 kg/km
TCX® ( C ) 331 150/250V 24P0.75
Nexans ref. 10184542
- Packaging: Cut to length (m)
- Number of pairs: 24
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 30.0 mm
- Maximum outer diameter: 34.0 mm
- Approximate weight: 981 kg/km
TCX® ( C ) 331 150/250V 2T0.75
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 2
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 12.5 mm
- Maximum outer diameter: 14.5 mm
- Approximate weight: 230 kg/km
TCX® ( C ) 331 150/250V 4T0.75
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 4
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 15.5 mm
- Maximum outer diameter: 17.5 mm
- Approximate weight: 330 kg/km
TCX® ( C ) 331 150/250V 7T0.75
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 7
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 18.5 mm
- Maximum outer diameter: 21.0 mm
- Approximate weight: 480 kg/km
TCX® ( C ) 331 150/250V 10T0.75
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 10
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 20.5 mm
- Maximum outer diameter: 26.5 mm
- Approximate weight: 670 kg/km
TCX® ( C ) 331 150/250V 2P1.5
Nexans ref. 10132031
- Packaging: Cut to length (m)
- Number of pairs: 2
- Number of triples: -
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 9.8 mm
- Maximum outer diameter: 11.5 mm
- Approximate weight: 180 kg/km
TCX® ( C ) 331 150/250V 4P1.5
Nexans ref. 10280640
- Packaging: Cut to length (m)
- Number of pairs: 4
- Number of triples: -
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 16.0 mm
- Maximum outer diameter: 18.5 mm
- Approximate weight: 370 kg/km
TCX® ( C ) 331 150/250V 7P1.5
Nexans ref. 10284324
- Packaging: Cut to length (m)
- Number of pairs: 7
- Number of triples: -
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 19.5 mm
- Maximum outer diameter: 23.0 mm
- Approximate weight: 553 kg/km
TCX® ( C ) 331 150/250V 10P1.5
Nexans ref. 10265071
- Packaging: Cut to length (m)
- Number of pairs: 10
- Number of triples: -
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 25.5 mm
- Maximum outer diameter: 27.0 mm
- Approximate weight: 764 kg/km
TCX® ( C ) 331 150/250V 14P1.5
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: 14
- Number of triples: -
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 27.5 mm
- Maximum outer diameter: 31.0 mm
- Approximate weight: 980 kg/km
TCX® ( C ) 331 150/250V 19P1.5
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: 19
- Number of triples: -
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 31.0 mm
- Maximum outer diameter: 34.5 mm
- Approximate weight: 1260 kg/km
TCX® ( C ) 331 150/250V 1T1.5
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 1
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 9.8 mm
- Maximum outer diameter: 11.5 mm
- Approximate weight: 230 kg/km
TCX® ( C ) 331 150/250V 2T1.5
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 2
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 15.0 mm
- Maximum outer diameter: 17.0 mm
- Approximate weight: 330 kg/km
TCX® ( C ) 331 150/250V 4T1.5
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 4
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 18.5 mm
- Maximum outer diameter: 21.0 mm
- Approximate weight: 490 kg/km
TCX® ( C ) 331 150/250V 7T1.5
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 7
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 22.0 mm
- Maximum outer diameter: 25.0 mm
- Approximate weight: 730 kg/km
Description
Description
Standards
-
ProductIEC 60228
-
InstallationIEC 60092-350; IEC 60092-360; IEC 60092-376
-
TestIEC 60331-1 or 2; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034
Application
TCX® (C) 331 150/250 V fire resistant armoured twisted pair cables maintain circuit integrity in case of fire by meeting performances requirements from the IEC 60331 series for 90 minutes. These telecommunication and instrumentation cables show a low transfer impedance in low frequency and an effective screening in high frequency, making them very suitable for polluted electromagnetic surroundings. TCX(C) 331 cables are used for detection and warning systems where enhanced mechanical protection is required. Designed with halogen-free fire retardant materials, they provide optimum safety for people and maximal asset protection against all risks of fire.
Design
-
Conductor:
Stranded bare copper
Class 2 -
Insulation:
Mica tape + XLPE (cross-linked polyethylene)
Optional: Special fire resistant HF 90 (halogen-free compound)
with INFITTM technology -
Inner covering:
Lapped polyester tape -
Armouring:
Bare copper braid -
Outer sheath:
Polyolefin SHF1 (SHF2 on request)
Colour: orange
Marking
I NEXANS I TCX (C) 331 150/250 V "n" 2 or 3 "s" mm² 90°C IEC 60092-376 IEC 60332-3-22 Cat. A IEC 60331-1/2 "ww/yy" * CE * TCF + metric marking
Core identification
- Core 1 : white
- Core 2 : blue
- Core 3: red
- Double identification: pair and conductor
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania